Radiološki vjesnik

radiologija • radioterapija • nuklearna medicina

Treba li nam sustav za ocjenu kvalitete radiološke slike u konvencionalnoj radiografiji?

Professional paper (Stručni rad)

Ivana Kralik1,2,3, Danijel Cvetko1, Zdenko Vojvodić1,2, Viktor Gregurić1, Dario Mesarić3, Ivana Bjelobrk4, Ana Buinac5, Mihaela Justić6, Katarina Ružić5, Dario Faj7,8

1 Klinička bolnica Dubrava, Zagreb
2 Medicinski fakultet Sveučilišta u Zagrebu, Zagreb
3 Zdravstveno veleučilište, Zagreb
4 Klinički bolnički centar Osijek, Osijek
5 Klinički bolnički centar Zagreb, Zagreb
6 Klinička bolnica Merkur, Zagreb
7 Medicinski fakultet Osijek, Osijek
8 Fakultet za dentalnu medicinu i zdravstvo Osijek, Osijek

Corresponding author: Ivana Kralik, Dubrava University Hospital, Ova e-mail adresa je zaštićena od spambota. Potrebno je omogućiti JavaScript da je vidite.

DOI: https://doi.org/10.55378/rv.48.2.5

Sažetak:

Cilj:  

Metode: Studija je provedena retrospektivno, usporedbom kvalitete radiološke slike i načina dobivanja radiološke slike. Ocijenjeno je 20 radioloških slika zdjelice, a ocjena je provedena prema europskim kriterijima za kvalitetu radiološke slike zdjelice. Kvalitetu slike su ocjenjivali radiolog, radiološki tehnolog i student radiološke tehnologije. Usporedbom s istim kriterijem analiziran je i način rada pri oslikavanju zdjelice u 3654 pacijenta te srca i pluća u 57758 pacijenata. Analizirana je i praksa sužavanja rendgenskog snopa na područje od interesa za 50 radioloških slika srca i pluća.

Rezultati: Samo jedna slika zdjelice ocijenjena je najvećom mogućom ocjenom od strane sva tri ocjenitelja. Subjektivne procjene ocjenitelja vezano uz odabir parametara ekspozicije razlikovale su se u većini ocjenjivanih slika zdjelice. Naponi na rendgenskoj cijevi korišteni pri oslikavanju zdjelice većinom su bili u preporučenom rasponu, dok su za srce i pluća u većini slučajeva bili manji od preporučene vrijednosti. Zdjelice su većinom oslikavane korištenjem udaljenosti žarišta rendgenske cijevi od prijemnika slike koje su bile u prihvatljivom rasponu osim u slučaju onih pacijenata koji su za vrijeme oslikavanja stajali. U slučaju oslikavanja srca i pluća ove su udaljenosti uglavnom bile u prihvatljivom rasponu osim u slučaju ležećih pacijenata kada je veći broj pacijenata oslikan korištenjem manjih udaljenosti. Svih 50 analiziranih radioloških slika srca i pluća bilo je uređeno na način da su po provedenom oslikavanju uklonjeni rubni dijelovi slike.

Zaključci: Rezultati provedene analize ukazuju na potrebu uspostave i provedbe sustava za ocjenu kvalitete radiološke slike koji bi uključivao i analizu načina rada.

Ključne riječi: kvaliteta radiološke slike, ekspozicijski indeks, napon na rendgenskoj cijevi, udaljenost žarišta od rendgenske cijevi, kolimacija

Do we need an image quality evaluation system in conventional radiography?

Abstract:

Aim: This work aims to point out the importance of establishing a system for image quality evaluation in conventional radiography.

Methods: The study was conducted retrospectively and it included image quality evaluation as well as analysis of imaging procedure. 20 radiographic images of pelvis were evaluated and the evaluation was carried out according to the European criteria for the quality of the radiographic images of pelvis. The imaging procedure was analysed using 3,651 radiographic images of the pelvis and 57,758 radiographic images of the chest. The analysis of the imaging procedure was carried out by comparing the used values ​​with the recommended ones. The practice related to narrowing the X-ray beam to the area of ​​interest using 50 radiological images of the chest was additionally analysed.

Results: Only one radiographic images of the pelvis were given the highest possible grade. Subjective evaluations of evaluators related to the selection of exposure parameters differed in the majority of evaluated pelvic images (80%). The X-ray tube voltages used during pelvic imaging were mostly in the recommended range but in case of imaging of chest X-ray tube voltage were lower than the recommended value in most cases. Pelvis were mostly imaged using X-ray tube source-to-detector distances that were within an acceptable range except for those patients who were standing during imaging. In the case of heart and lung imaging, these distances were generally in the acceptable range except in the case of supine patients when a larger number of patients were imaged using smaller distances. All 50 analysed radiological images of the chest were cropped.

Conclusions: The results of the analysis indicate the need to establish and implement a system for evaluating the quality of radiographic images, which would also include an analysis of the imaging procedure.

Key words: image quality, exposure index, tube voltage, source-to-detector distance, collimation 

 